จันทร์–ศุกร์ 08:30–17:30โทร 02-028-6074LINE @pakoeng
ขอใบเสนอราคา

WELL | FLOWMETER | Z-500SW Series

Flowmeter Z-500SW series can be installed on the pipeline flowmeter, can be alarmed in any position, easy to installation, dependable , especially to add install to the equipment. It can be alarmed in any position. When the float reach up or over to settle position for the flow. it will put out signal, then contact point will be clos

Model Z-5008CSW | 1/2" Z-5008SW | 1/2" Z-5015SW | 1//2" Z-5025SW | 3/4" Z-5032SW | 1"
Connection เกลียว
Selection Limit Switch : Lower Limit Switch : Upper Limit Switch : Upper&Lower
Flow Range (Unit : L/min) 0.5-4 (Unit : L/min) 1-10 (Unit : L/min) 1-7 (Unit : L/min) 1.8-18 (Unit : L/min) 3-30 (Unit : L/min) 4-40 (Unit : L/min) 5-50 (Unit : L/min) 8-80 (Unit : L/min) 10-100

ช่องทางสั่งซื้อออนไลน์ (ออกใบกำกับภาษีทุกช่องทาง)

สินค้ารายการดังกล่าวยังไม่รองรับการสั่งซื้อผ่าน Shopee หรือ Lazada โปรดติดต่อเจ้าหน้าที่ Line: @pakoeng

เอกสารประกอบ

ดาวน์โหลดสเปคสินค้าขั้นตอนขอใบเสนอราคา

*เนื่องจากสินค้าบางรายการของทางบริษัท จำเป็นต้องระบุรายละเอียดหลายขั้นตอน สอบถามรายละเอียดได้ที่ sales@pako.co.th

pressure gauge diaphragm seal valve pako engineering qr code

เพิ่มเพื่อนขอใบเสนอราคาได้ที่ LINE Official :  @pakoeng

WELL | FLOWMETER | Z-500SW Series

Flowmeter Z-500SW series can be installed on the pipeline flowmeter, can be alarmed in any position, easy to installation, dependable , especially to add install to the equipment. It can be alarmed in any position. When the float reach up or over to settle position for the flow. it will put out signal, then contact point will be clos

Additional information

Application

Flowmeter Z-500SW series can be installed on the pipeline flowmeter, can be alarmed in any position, easy to installation, dependable , especially to add install to the equipment. It can be alarmed in any position. When the float reach up or over to settle position for the flow. it will put out signal, then contact point will be clos

Supply and Function

Z-500SW (Upper Limit) – When magnetic float reach up or over to the settle position, the contact point will be closed and when magnetic float lower than settle position, contact position will be cut off. Z-500SW (Lower Limit) – When magnetic float reach up or lower than settle position, the contact point will be closed when magnetic float over than settle position, contact point will be cut off.

Technical Parameter

Working Preesure : max. DC24/AC24 Operating Current : max.0.3A Permanent Current : max. DC0.1A Rupturing Capacity : max. 1VA Forward Resistance : < 200mΩ Insulating Impedance : > 109Ω Working Temperature : 0 °C to +55 °C Protection Grade : IP65 Lag Behind : 4 mm. Sizes : 45 x 20 x 45

Material

Body : Polysulfone (PSU), PC Connection : PVC, ABS Float : ABS, SS304, SS316 Guide rod : SS304 O-ring : EPDM

ลิงก์ที่เกี่ยวข้อง

บทความ

วิดีโอ

รุ่นอื่นในหมวดเดียวกัน

ดูสินค้าทั้งหมด →

ไม่แน่ใจว่าต้องใช้รุ่นไหน ส่งสเปกงานมาได้เลย

ทีมวิศวกรช่วยเลือกรุ่นและออกใบเสนอราคาให้ภายในวันทำการเดียวกัน